Chemical Equivalence Of Different Brands Of Oxytertacycline Hydrochloride And Its Minimum (Record no. 3174)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 01877nam a2200193Ia 4500 |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20151006130318.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 150525s2012 xx 000 0 und d |
041 ## - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER | |
Classification number | 1468,T |
100 ## - MAIN ENTRY--AUTHOR NAME | |
Personal name | Sadaf Hina |
110 ## - MAIN ENTRY--CORPORATE NAME | |
Location of meeting | Prof. Dr. Muhammad Ashraf |
245 ## - TITLE STATEMENT | |
Title | Chemical Equivalence Of Different Brands Of Oxytertacycline Hydrochloride And Its Minimum |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Year of publication | 2012 |
502 ## - DISSERTATION NOTE | |
Dissertation note | This project was designed to study the chemical equivalence of various brands of Oxytetracycline hydrochloride (long acting, short acting & PVP) approved by the ministry of health and available in the local market for veterinary use. Oxytetracycline was measured by HPLC method developed and standardized in the laboratory. Limit of detection (LOD) and limit of quantification (LOQ) of the Oxytetracycline by HPLC assay method were determined. From stock solution of working standard (Oxytetracycline hydrochloride) different concentrations 0.05, 0.1, 0.5, 1.0, 10, 25, 50 and 100µg per ml were prepared for the determination of LOD. The LOD calculated was 0.100(µg/ml) and LOQ was 0.5 (µg/ml). Correlation coefficient was 0.99994050. Concentration of the active ingredient (Oxytetracycline hydrochloride) in all preparations was same as mentioned on the label except Oxytetracycline (74%), Terrasym PVP-100 (81%), and Onyx-LA (72%). MIC of Oxytetracycline hydrochloride against following bacterial isolates determined by micro-broth dilution test was Bacillus subtilis (50µg), Staphylococcus aureus (100µg), Eschericiha coli (50µg), Salmonella enterica (1000µg) and Pasturella multocida (50µg).It showed that all these bacterial cultures have developed resistance against Oxytetracycline hydrochloride. |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical Term | Department of Pharmaoclogy & Toxicology |
700 ## - ADDED ENTRY--PERSONAL NAME | |
Personal name | Dr. Aftab |
700 ## - ADDED ENTRY--PERSONAL NAME | |
Personal name | Dr. Muhammad Adil Rasheed |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Koha item type | Thesis |
Damaged status | Collection code | Permanent Location | Current Location | Shelving location | Date acquired | Full call number | Accession Number | Koha item type |
---|---|---|---|---|---|---|---|---|
Veterinary Science | UVAS Library | UVAS Library | Thesis Section | 2015-05-29 | 1468,T | 1468,T | Thesis |