Normal view MARC view ISBD view

Comparison Of Single And Stack Pinning Techniques For Mid Shaft Femoral Fracture In The Dog

By: Kamran Akhtar | Dr. Mazhar Iqbal.
Contributor(s): Dr. Muhammad Arif | Dr. S | Faculty of Veterinary Sciences.
Material type: materialTypeLabelBookPublisher: 1995Subject(s): Department of Clinical Medicine & SurgeryDDC classification: 0415,T Dissertation note: The incidence of femoral fracture is higher than that of other long bones in clogs. Immobilization of Fernoral fractures by external method of fixation is almost impossible due to angulation of the hind limbs, thickness of thigh musculature and difficulty of controlling motion in the hip joint. This type of orthopeadic ailment can he handled successfully with hone splintage principle which, includes the use of compression plates, cerciage wires, and intrarneclullary pins. In this project stack pinning and single intramedullary pinning with hemicerciage wires were used to treat midshaft transverse femoral fractures n the clog. The procedure was conducted on 20 mongrel dogs of either sex, divided into two groups of 10 clogs each . In group I the surgically created mid shaft femoral Fracture was immobilized using single intramedullary pin with hemicerclage wires. Whereas in group II the fracture was immobilized with stack pinning. First pin was introduced in a retrograde and the second pin in a normograde fashion. All the dogs were kept in Kennels For a period of sixteen weeks and results were collected on the basis of clinical and radiographic evulations. All the clogs were euthanisecl at the end of experimental period and operation sites were explored to find out the gross changes The analysis of the results clearly indicated that intramedullary pinning with hemicerclage wires was a better choice over stack pinning for repairing mid shaft transverse femoral Fractures.
Tags from this library: No tags from this library for this title. Add tag(s)
Log in to add tags.
    average rating: 0.0 (0 votes)

The incidence of femoral fracture is higher than that of other long bones in clogs. Immobilization of Fernoral fractures by external method of fixation is almost impossible due to angulation of the hind limbs, thickness of thigh musculature and difficulty of controlling motion in the hip joint. This type of orthopeadic ailment can he handled successfully with hone splintage principle which, includes the use of compression plates, cerciage wires, and intrarneclullary pins. In this project stack pinning and single intramedullary pinning with hemicerciage wires were used to treat midshaft transverse femoral fractures n the clog. The procedure was conducted on 20 mongrel dogs of either sex, divided into two groups of 10 clogs each .

In group I the surgically created mid shaft femoral Fracture was immobilized using single intramedullary pin with hemicerclage wires. Whereas in group II the fracture was immobilized with stack pinning. First pin was introduced in a retrograde and the second pin in a normograde fashion. All the dogs were kept in Kennels For a period of sixteen weeks and results were collected on the basis of clinical and radiographic evulations. All the clogs were euthanisecl at the end of experimental period and operation sites were explored to find out the gross changes

The analysis of the results clearly indicated that intramedullary pinning with hemicerclage wires was a better choice over stack pinning for repairing mid shaft transverse femoral Fractures.

There are no comments for this item.

Log in to your account to post a comment.


Implemented and Maintained by UVAS Library.
For any Suggestions/Query Contact to library or Email:rehana.kousar@uvas.edu.pk Phone:+91 99239068
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.