Comparative Efficacy Of Intramedullary Pilling And Cerclage Wiring For The Repair Of Long Oblique Tibiotarsus Fracture In Avian
By: Waqar Azeem | Dr.Muhammad Arif khan.
Contributor(s): Dr. Muhammad | Dr.Asim Khalid Mahmood | Faculty of Veterinary Sciences.
Material type: BookPublisher: 2003Subject(s): Department of Clinical Medicine & SurgeryDDC classification: 0828,T Dissertation note: The present project was designed t find out most effective and accurate method of internal fixation in avian long oblique tibiotarsal fracture repair. For this purpose 12 indigenous chickens of both sexes were selected and randomly divided into three groups i.e. A, B and C comprising four birds each. Long oblique tibiotarsal fractures were created in either of the limb. In group A these fractures were repaired with single intramedullaiy pin. K.E. wire f 2.5mm diameter was used for this purpose. In group B, 2 - 3 full cerclage wires were applied where as both these techniques were used simultaneously in the birds of group C to achieve the goal of fracture stabilization. The birds were kept uptil 8 weeks post operatively. The fracture healing procedure was monitored on weekly basis. The birds were slaughtered at the end of experiments period and postmortem examination was conducted to see the gross lesion over the fracture site. The data thus obtained from the results revealed that the use of single intra medullaiy pin along with 2 - 3 full cerciage wire application showed an excellent and smooth healing potential for the repair of long oblique tibiotarsal fracture.Item type | Current location | Collection | Call number | Status | Date due | Barcode | Item holds |
---|---|---|---|---|---|---|---|
Thesis | UVAS Library Thesis Section | Veterinary Science | 0828,T (Browse shelf) | Available | 0828,T |
Browsing UVAS Library Shelves , Shelving location: Thesis Section , Collection code: Veterinary Science Close shelf browser
The present project was designed t find out most effective and accurate method of internal fixation in avian long oblique tibiotarsal fracture repair. For this purpose 12 indigenous chickens of both sexes were selected and randomly divided into three groups i.e. A, B and C comprising four birds each. Long oblique tibiotarsal fractures were created in either of the limb. In group A these fractures were repaired with single intramedullaiy pin. K.E. wire f 2.5mm diameter was used for this purpose. In group B, 2 - 3 full cerclage wires were applied where as both these techniques were used simultaneously in the birds of group C to achieve the goal of fracture stabilization. The birds were kept uptil 8 weeks post operatively. The fracture healing procedure was monitored on weekly basis. The birds were slaughtered at the end of experiments period and postmortem examination was conducted to see the gross lesion over the fracture site. The data thus obtained from the results revealed that the use of single intra medullaiy pin along with 2 - 3 full cerciage wire application showed an excellent and smooth healing potential for the repair of long oblique tibiotarsal fracture.
There are no comments for this item.